Vickers Type Hardness
Testers
|
|

KVM-250 |
SALIENT FEATURES
These machines come in two basic versions.i.e.Pure Vickers and Vickers cum Brinell. Load range for pure Vickers is from 1 kg. to 120 kg and for Vickers cum Brinell, 1 kg to 250 kg |
|
|
| |
| GENERAL : |
1. |
These machines are suitable for checking Vickers or Brinell Hardness of Steel and other metals. |
2. |
Loads are applied with dead weights and are selectable with push buttons. |
3. |
Measurement of Diagonal / Diameter of indentation is done with the help of built in optical system with with built-in micrometer scale. |
4. |
After taking the indentation on work piece , objective lens is automatically swiveled in position and indentation image appears on the focussing screen fitted in front of the machine. |
5. |
Loading cycle is started with Push Button in the front where-as unloading is done manually by hand lever. |
6. |
All models i.e.KVM-120, KVM-120S, KVM-250, KVM-250S confirm to IS 1754 & BS 427 for Vickers & IS 2281-1983, BS 240,ASTM-E-10 for Brinell Hardness. |
|
| |
| Technical Specifications |
| Model |
KVM-120 |
KVM-120-S |
KVM-250 |
KVM-250-S |
| Load (kgf) |
5,10,15,20,30,40,
50,60,100,120
(Load for Vickers) |
1,2,5,10,15,20,30,40,
50,60,100 and 120 (Load for Vickers) |
5,10,15,20,30,40,
50,60,100 & 120
(Load and Vickers)
15.625,31,25,62.5,
187.5, 250
(Load for Brinell) |
1,2,5,10,15,20,30,
40,50,60,100, & 120
(Load for Vicker)
15.625,31,25,62.5
(Load for Brinell) |
| Optical Magnifaction |
70x,140x |
70x, 140x, |
35x,70x,140x, |
35x,70x,140x, |
| Max. Test Height (mm) |
250 |
250 |
250 |
250 |
| Sweep of machine frame (mm) |
150 |
150 |
150 |
150 |
| Weight Approx(Kgs) |
180 |
180 |
180 |
180 |
Dimensions
(L X W X H mm) appr |
650 x 320 x 990 |
650 x 320 x 1130 |
650 x 320 x 990 |
650 x 320 x 1130 |
| Connected load |
0.1 KVA, 1 PHASE AC, 220 V, 50Hz |
| Load can be supplied in Newtons also Least count of Optical System 0.0005 mm |
|
| |
| Measuring Range Possible w.r.t selected Optical magnification |
1) |
0-3.2 mm |
on |
35X |
Magnification |
| 2) |
0-1.6 mm |
on |
70X |
Magnification |
| 3) |
0-0.8 mm |
on |
140X |
Magnification |
|
| |
| STANDARD ACCESSORIES |
| |
| Model |
KVM - 120 |
KVM - 120-S |
KVM-250 |
KVm-250-s |
| Flat table of 100 mm Die |
1 NO. |
1 NO. |
1 NO. |
1 NO. |
| 'V' table for specimen - 6 to 80 mm Dia |
1 NO. |
1 NO. |
1 NO. |
1 NO. |
| Vickers Diamond Indentor |
1 NO. |
1 NO. |
1 NO. |
1 NO. |
| 2.5 mm Ball Indentor |
- |
- |
1 NO. |
1 NO. |
| 5.0 mm Ball Indentor |
- |
- |
1 NO. |
1 NO. |
| Vickers hardness Test Plate |
1 NO. |
1 NO. |
1 NO. |
1 NO. |
| Brinell Hardness Test Plate |
- |
- |
1 NO. |
1 NO. |
| Electrical Cord |
1 NO. |
1 NO. |
1 NO. |
1 NO. |
| Instruction manual |
1 Book |
1 Book |
1 Book |
1 Book |
| 2.5 mm Balls |
- |
- |
5 Nos. |
5 Nos. |
| 5 mm Balls |
- |
- |
5 Nos. |
5 Nos. |
|
| |
|
|
|
 |
|
|
|
|